FSP-851 Photoelectric Smoke Detectors

Smoke Detectors

Series 851 Series Photoelectric detector’s unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Intelligent detectors include point ID capability that enable each detector address to be set with rotary address switches to provide exact detector locations.

The sensitivity can be programmed using the control panel software to suit the environment. In addition, detector sensitivity is continually monitored and reported to the panel.

  • Photoelectric smoke detection
  • Analog communications
  • Low standby current
  • Rotary address switches
  • Dual LEDs for 360° visibility
  • Specifications
  • Voltage Range: 15-32 volts DC peak
  • Standby Current (max. avg.): 300µA @ 24V DC (one communication every five seconds with LED enabled)
  • LED Current (max.): 6.5mA @ 24V DC (‘ON’)

Certifications:

  • UL Listed: S1115
  • MEA Listed: 225-02-E
  • FM Approved
  • CSFM: 7272-0028:0206
  • Brand : NOTIFIER
  • Product Type : Intelligent Plug-In Smoke Detector
NameDateSize
FIRE DETECTION AND ALARM SYSTEM Engineering Specifications 2/26/2025565.39 KB
FSP-851-A- Series Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan Data Sheet 2/26/202587.06 KB
Important Updates - New Addressable Sensor Line in 2018 Product Bulletin 2/26/2025712.95 KB
Addressable Sensor Line Product Bulletin 2/26/2025778.22 KB
Fire Detection Panels- Detectors and Peripheral Equipment Certificate of Approvals 2/26/2025433.77 KB
Fire Detection Panels- Detectors and Peripheral Equipment Certificate of Approvals 2/26/2025594.11 KB
Lloyds Register Approval Appendix Certificate of Approvals 2/26/2025500.29 KB
Leaders in Life- Safety- Technology Catalogs 1/8/20249.8 MB
FSP-851AUS Series Photelectric Smoke Detector Data Sheet 1/8/2024190.88 KB
Notifier- Model FSP-851AUS-IV-FSP-851AUS-W- adjustable sensitivity- photoelectric smoke detector Declaration of Conformity 1/8/2024213.92 KB
851 Series detector Product Bulletin 1/8/2024230.01 KB
AGILE Wireless Fire Detection System Engineering Specifications 11/28/2023140.72 KB
AGILE Wireless Fire Detection System Engineering Specifications 11/28/2023846.24 KB
NOTIFIER Life Safety & Emergency Communications Systems Information Guide-Brochure 8/9/20232.68 MB
FSP-851(A) Data Sheet 3/20/202383.69 KB
Notifier-ALC-2018-Product-Line-Update Reference Guide 11/1/20215.44 MB
Ionization Smoke Detector- Remove- Recycle- Replace- Product Bulletin 11/1/2018332.8 KB
Addressable Sensor Line - Important Phase Out Dates Product Bulletin 1/1/2018445.63 KB
Isolator Load Rating Table Brochure 1/1/201655.33 KB
Base - Detector Cross Reference (Legacy) Brochure 10/30/2014119.23 KB
Addressable Detector Insertion and Removal Technical Bulletin 7/8/2003392.91 KB
New Line Of Detection Slide Presentation 10/9/20012.05 MB
FSP-851- FSP-851T and FAPT-851 Intelligent Photoelectric Smoke Sensors Installation Manual 6/22/1999705.84 KB
Notifier FireWarden Series Slide Presentation 12/18/1995917.67 KB
Part NumberDescription
FSP-851TFSP-851 Photoelectric Smoke Detectors, Operating temperature -32F to 100F

Subscribe to Our Newsletter

Join our community and stay updated with the latest news and updates delivered straight to your inbox.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.